统一服务热线:400-888-0207 在线咨询 | 微信联系
首页 > 产品 > 产品类型 > 试剂盒 > 多糖标记
LudgerTag V-Tag Glycopeptide Labeling and Enrichment Kit,V-Tag糖肽
货号:LT-VTAG-24 | 规格:24 samples | 价格:¥0.00 | 品牌:Ludger
Ludger V-Tag糖蛋白分析技术是一种为单克隆抗体研发和生物仿制药厂家提供的成本效益高的,经GMP认证的, 快速工具。
• 用于单克隆抗体药物整个生命周期的质量控制和生物相似性验证。
• 易于整合进您的肽图。它能提供多糖的定性,定量,结合位点 和 位点占有信息。
LudgerTag V-Tag糖肽标记和富集试剂盒
The LudgerTag V-tag labeling kit is designed for the fluorophore labeling of enzymatically digested peptides and glycopeptides followed by enrichment of the labeled glycopeptides. The V-tag labeled glycopeptides are analyzed using MALDI-MS and HPLC/UHPLC

The LudgerTag V-Tag Glycopeptide Labeling kit is designed for the fluorophore labeling of enzymatically digested peptides and glycopeptides followed by enrichment of the labeled glycopeptides. Labeled glycopeptides can be separated using MALDI-MS and HILIC HPLC or UHPLC chromatography. We recommend the LudgerSep N2 HILIC column (LS-N2-2.0X150) for HPLC or columns such as the Waters BEH Glycan 2mm x 150 mm for UHPLC.

The method provides both glycan identity and quantitation as well as glycan attachment site and site occupancy

Reliable mAb Glycoprofiling – Provides MALDI-MS and UHPLC data comparable to the gold-standard 2-AB and 2-AA methods
Quick and Easy – Labeling and enrichment in 2 hours
Minimal Sample Needed – Use as little as 10 µgs of mAb glycoprotein
Validated for GMP Labs – Validated to ICH Q2(R1) standards and tested in glycoprofiling labs
High-throughput Compatibility – Ready for 96-well based assay automation

Dye Properties: Mass = 434.42 (resulting in a glycopeptide mass increase of 319.33 Da.) FluorescenceL ex = 250 nm, em = 360 nm.

Number of Samples: 24 separate analytical samples per kit.

Amount of Sample: From approximately 1 µg to 50 µg of glycoprotein per sample.

Suitable Samples: IgG single subclass glycoproteins. Other glycoproteins can be used, but note that if there are multiple glycosylation sites, the glycopeptides may need to be separated by C18 HPLC before HILIC analysis. It is recommended that samples do not have amine containing solvents (e.g. Tris type buffers) or reduction/alkylation agents as they will interfere with the V-tag labeling. Removal of the amine containing solvents and reduction/alkylation agents can be accomplished using devices which are designed for desalting and buffer exchange, as well as removal of low-molecular weight compounds

Labeling Selectivity: One V-tag label for every IgG glycopeptide N-terminus.

Storage: Store the V-tag dye at -20˚C in the dark. Protect from sources of heat, light and moisture. Once used, extra dye solution can be frozen and re-used.